TetraForce-Cut- Implant – AH725

IMPROVED TOOL LIFE

Good chip evacuation
- The conventional insert often fractured when machining up to 2000 pcs/C due to high cutting resistance resulted from the chipbreaker. With a sharp cutting edge and dimpled chipbreaker, TetraForce-Cut provides excellent chip evacuation and stable machining in the machining of stainless steel!

High wear resistance
- The combination with AH725, which has a good balance between wear resistance and fracture resistance, achieves 1.5 times longer tool life (3000 pcs/C).

TetraForce-Cut
Industry Medical
Component Implant
Material ISO code M - Stainless steelM - Stainless steel
Work material X6CrNiMoTi17-12-2
Machine(spindle type) Multi-axis Lathe
Tool family Grooving
Tool category Parting off
Product name TetraForce-Cut
TSR No. 251T
Implant

Tool

Tungaloy Competitor

Cutting conditions

Tungaloy Competitor

Result

Tool life1.5 times